اندازه گیری زاویه کوادریسپس توسط دستگاه و روش جدید و مقایسه آن با روش متداول گونیامتری و روش مرجع رادیوگرافی در مردان سالم
General Material Designation
[پایاننامه]
Parallel Title Proper
comparison between a goniometer an dnew method for measuringquadriceps angle in contrast with Radiography
.PUBLICATION, DISTRIBUTION, ETC
Name of Publisher, Distributor, etc.
علوم بهزیستی و توانبخشی university of social welfare and rehabilitation))
Date of Publication, Distribution, etc.
، ۱۳۸۸
PHYSICAL DESCRIPTION
Specific Material Designation and Extent of Item
۷۹ص.
GENERAL NOTES
Text of Note
پیوست
NOTES PERTAINING TO PUBLICATION, DISTRIBUTION, ETC.
Text of Note
چاپی
DISSERTATION (THESIS) NOTE
Dissertation or thesis details and type of degree
کارشناسی ارشد
Discipline of degree
فیزیوتراپی physical therapy
Body granting the degree
علوم بهزیستی و توانبخشی university of social welfare and rehabilitation))
SUMMARY OR ABSTRACT
Text of Note
Introduction Measurement error when determining the size of an angle is always an issue for clinicians.Computer assistance may help to decrease that error. The purpose of this study is to decrease the amount of error when measuring Q-angles using a goniometer by the New Method, a Private system developed at the I.R's University of State Welfare & Rehabilitation by Investigator.Method Fourty subjects with Eighty healthy knees participated in this study. One investigator participated in data collection who is a licensed physical therapist who has over 6 years of clinical practice in orthopedic physical therapy , He has designed and experienced with New Method and computer program. Quadriceps angles measured bilaterally for 40 subjects between the ages of 20 and 29 years were recorded. Reliability and validity with New Method of the measurements were calculated with ICC & Repeated Measurement for New Method and compared it's result with Goniometry in contrast with Radiography. Result The ICC for measuring Q-angle with a New Method versus the radiography was .935,while the ICC for measuring Q-angle with the goniometry versus the radiography was.696. The ICC between measures three times obtained with a New Method was .974.Discussion There is a high association between measures of Q-angle obtained with a New Method compared to those obtained with Radiography while this association for Goniometry is low. Repeatability for New measurement Method is good for One investigator. Further investigations should be conducted to examine the feasibility of increased use of New Metod in measuring angles Keyword: Q-angle, measurement, New Method, Radiography, Goniometry This
ba
PARALLEL TITLE PROPER
Parallel Title
comparison between a goniometer an dnew method for measuringquadriceps angle in contrast with Radiography