اندازه گیری زاویه کوادریسپس توسط دستگاه و روش جدید و مقایسه آن با روش متداول گونیامتری و روش مرجع رادیوگرافی در مردان سالم
نام عام مواد
[پایاننامه]
عنوان اصلي به زبان ديگر
comparison between a goniometer an dnew method for measuringquadriceps angle in contrast with Radiography
وضعیت نشر و پخش و غیره
نام ناشر، پخش کننده و غيره
علوم بهزیستی و توانبخشی university of social welfare and rehabilitation))
تاریخ نشرو بخش و غیره
، ۱۳۸۸
مشخصات ظاهری
نام خاص و کميت اثر
۷۹ص.
يادداشت کلی
متن يادداشت
پیوست
یادداشتهای مربوط به نشر، بخش و غیره
متن يادداشت
چاپی
یادداشتهای مربوط به پایان نامه ها
جزئيات پايان نامه و نوع درجه آن
کارشناسی ارشد
نظم درجات
فیزیوتراپی physical therapy
کسي که مدرک را اعطا کرده
علوم بهزیستی و توانبخشی university of social welfare and rehabilitation))
یادداشتهای مربوط به خلاصه یا چکیده
متن يادداشت
Introduction Measurement error when determining the size of an angle is always an issue for clinicians.Computer assistance may help to decrease that error. The purpose of this study is to decrease the amount of error when measuring Q-angles using a goniometer by the New Method, a Private system developed at the I.R's University of State Welfare & Rehabilitation by Investigator.Method Fourty subjects with Eighty healthy knees participated in this study. One investigator participated in data collection who is a licensed physical therapist who has over 6 years of clinical practice in orthopedic physical therapy , He has designed and experienced with New Method and computer program. Quadriceps angles measured bilaterally for 40 subjects between the ages of 20 and 29 years were recorded. Reliability and validity with New Method of the measurements were calculated with ICC & Repeated Measurement for New Method and compared it's result with Goniometry in contrast with Radiography. Result The ICC for measuring Q-angle with a New Method versus the radiography was .935,while the ICC for measuring Q-angle with the goniometry versus the radiography was.696. The ICC between measures three times obtained with a New Method was .974.Discussion There is a high association between measures of Q-angle obtained with a New Method compared to those obtained with Radiography while this association for Goniometry is low. Repeatability for New measurement Method is good for One investigator. Further investigations should be conducted to examine the feasibility of increased use of New Metod in measuring angles Keyword: Q-angle, measurement, New Method, Radiography, Goniometry This
خط فهرستنویسی و خط اصلی شناسه
ba
عنوان اصلی به زبان دیگر
عنوان اصلي به زبان ديگر
comparison between a goniometer an dnew method for measuringquadriceps angle in contrast with Radiography
موضوع (اسم عام یاعبارت اسمی عام)
موضوع مستند نشده
Q-angle
مقوله موضوعی
متن عنصر شناسه ای مقوله موضوعی
زاویه کوادریسپس
متن عنصر شناسه ای مقوله موضوعی
Q-angle
نام شخص به منزله سر شناسه - (مسئولیت معنوی درجه اول )