Interrupted curing, recuring, and the duration of curing of plain and pozzolanic concretes

پدید آورنده
M. S. Khan

موضوع
Applied sciences,Civil engineering,concrete,Materials science

رده

کتابخانه
Center and Library of Islamic Studies in European Languages

محل استقرار
استان: Qom ـ شهر: Qom

Center and Library of Islamic Studies in European Languages

تماس با کتابخانه : 32910706-025

NATIONAL BIBLIOGRAPHY NUMBER

Number
TLpq304008457

LANGUAGE OF THE ITEM

.Language of Text, Soundtrack etc
انگلیسی

TITLE AND STATEMENT OF RESPONSIBILITY

Title Proper
Interrupted curing, recuring, and the duration of curing of plain and pozzolanic concretes
General Material Designation
[Thesis]
First Statement of Responsibility
M. S. Khan
Subsequent Statement of Responsibility
M. E. Ayers

.PUBLICATION, DISTRIBUTION, ETC

Name of Publisher, Distributor, etc.
Oklahoma State University
Date of Publication, Distribution, etc.
1992

PHYSICAL DESCRIPTION

Specific Material Designation and Extent of Item
185

DISSERTATION (THESIS) NOTE

Dissertation or thesis details and type of degree
Ph.D.
Body granting the degree
Oklahoma State University
Text preceding or following the note
1992

SUMMARY OR ABSTRACT

Text of Note
Scope and method of study. The losses in strength and permeability of plain cement, fly ash, and silica fume mortars and concretes, due to an interruption in moist curing, and subsequent regain in these properties due to recuring were investigated. In addition, the curing requirements of silica fume mortars and concretes were determined and compared with those of plain cement and fly ash mortars and concretes. The initial tests were performed on mortars (50-mm cubes), where the specimens were moist cured for 0, 3, 7, 14, and 28 days. After each moist curing period, the curing was interrupted by oven-drying the specimens at a temperature of 110C (230F) for 3 days. The specimens were then divided into two groups; one group was recured, while the curing of the other group was discontinued. At the end of the recuring period, both groups of specimens were tested for compressive strength and coefficient of absorptivity. The study was later expanded to include concrete mixes, typically used in highway construction. These tests utilized larger size specimens (100 x 200-mm cylinders), and a moderate environment (room-drying) for curing interruption. Findings and conclusions. The data clearly demonstrate the detrimental effects of interrupted curing, particularly when the environment of curing interruption was harsh (oven-drying), the curing was interrupted at an early stage, or fly ash was used in the mortar or concrete. However, significant regain in the properties of mortars and concretes were achieved when the specimens were recured. Regression Equations developed from the data obtained in this study estimate the minimum lengths of curing for silica fume, fly ash, and plain cement (ASTM Type I) concretes as 3 days, 6.5 days, and 3.75 days, respectively. These results suggest that the current industry practice of over-curing silica fume concrete is unnecessary.

TOPICAL NAME USED AS SUBJECT

Applied sciences
Civil engineering
concrete
Materials science

PERSONAL NAME - PRIMARY RESPONSIBILITY

M. E. Ayers
M. S. Khan

ELECTRONIC LOCATION AND ACCESS

Electronic name
 مطالعه متن کتاب 

p

[Thesis]
276903

a
Y

Proposal/Bug Report

Warning! Enter The Information Carefully
Send Cancel
This website is managed by Dar Al-Hadith Scientific-Cultural Institute and Computer Research Center of Islamic Sciences (also known as Noor)
Libraries are responsible for the validity of information, and the spiritual rights of information are reserved for them
Best Searcher - The 5th Digital Media Festival