• صفحه اصلی
  • جستجوی پیشرفته
  • فهرست کتابخانه ها
  • درباره پایگاه
  • ارتباط با ما
  • تاریخچه

عنوان
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2

پدید آورنده
Aad, GAbbott, BAbbott, DCAbdinov, OAbud, AAAbeling, KAbhayasinghe, DKAbidi, SHAbouzeid, OSAbraham, NLAbramowicz, HAbreu, HAbulaiti, YAcharya, BSAchkar, BAdachi, SAdam, LBourdarios, CAAdamczyk, LAdamek, LAdelman, JAdersberger, MAdiguzel, AAdorni, SAdye, Tet al.

موضوع

رده

کتابخانه
مرکز و کتابخانه مطالعات اسلامی به زبان‌های اروپایی

محل استقرار
استان: قم ـ شهر: قم

مرکز و کتابخانه مطالعات اسلامی به زبان‌های اروپایی

تماس با کتابخانه : 32910706-025

شماره کتابشناسی ملی

شماره
LA0c34109b

عنوان و نام پديدآور

عنوان اصلي
Resolution of the ATLAS muon spectrometer monitored drift tubes in LHC Run 2
نام عام مواد
[Article]
نام نخستين پديدآور
Aad, GAbbott, BAbbott, DCAbdinov, OAbud, AAAbeling, KAbhayasinghe, DKAbidi, SHAbouzeid, OSAbraham, NLAbramowicz, HAbreu, HAbulaiti, YAcharya, BSAchkar, BAdachi, SAdam, LBourdarios, CAAdamczyk, LAdamek, LAdelman, JAdersberger, MAdiguzel, AAdorni, SAdye, Tet al.

یادداشتهای مربوط به خلاصه یا چکیده

متن يادداشت
© 2019 CERN for the benefit of the ATLAS collaboration. Published by IOP Publishing Ltd on behalf of Sissa Medialab. Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. The momentum measurement capability of the ATLAS muon spectrometer relies fundamentally on the intrinsic single-hit spatial resolution of the monitored drift tube precision tracking chambers. Optimal resolution is achieved with a dedicated calibration program that addresses the specific operating conditions of the 354 000 high-pressure drift tubes in the spectrometer. The calibrations consist of a set of timing offsets and drift time to drift distance transfer relations, and result in chamber resolution functions. This paper describes novel algorithms to obtain precision calibrations from data collected by ATLAS in LHC Run 2 and from a gas monitoring chamber, deployed in a dedicated gas facility. The algorithm output consists of a pair of correction constants per chamber which are applied to baseline calibrations, and determined to be valid for the entire ATLAS Run 2. The final single-hit spatial resolution, averaged over 1172 monitored drift tube chambers, is 81.7 ± 2.2 μm.

مجموعه

تاريخ نشر
2019
عنوان
Lawrence Berkeley National Laboratory

دسترسی و محل الکترونیکی

نام الکترونيکي
 مطالعه متن کتاب 

اطلاعات رکورد کتابشناسی

نوع ماده
[Article]
کد کاربرگه
279020

اطلاعات دسترسی رکورد

سطح دسترسي
a
تكميل شده
Y

پیشنهاد / گزارش اشکال

اخطار! اطلاعات را با دقت وارد کنید
ارسال انصراف
این پایگاه با مشارکت موسسه علمی - فرهنگی دارالحدیث و مرکز تحقیقات کامپیوتری علوم اسلامی (نور) اداره می شود
مسئولیت صحت اطلاعات بر عهده کتابخانه ها و حقوق معنوی اطلاعات نیز متعلق به آنها است
برترین جستجوگر - پنجمین جشنواره رسانه های دیجیتال