بررسی اعتبارسنجی ابزار مجموعه حداقل دادههای برنامه مراقبت در منزلHC) - (MDSدر سالمندان ایرانی :مطالعه روایی و پایایی
General Material Designation
[پایاننامه]
Parallel Title Proper
Psychometric Properties evaluation of Minimum Data Set-Home Care (MDS-HC) in Iranian elderly household residents: A Validity and Reliability Study
.PUBLICATION, DISTRIBUTION, ETC
Name of Publisher, Distributor, etc.
علوم بهزیستی و توانبخشیUniversity of Social Welfare and Rehabilitation))
Date of Publication, Distribution, etc.
، ۱۳۹۷
PHYSICAL DESCRIPTION
Specific Material Designation and Extent of Item
۱۸۱ص.
GENERAL NOTES
Text of Note
پیوست
NOTES PERTAINING TO PUBLICATION, DISTRIBUTION, ETC.
Text of Note
چاپی
DISSERTATION (THESIS) NOTE
Dissertation or thesis details and type of degree
دکترا
Discipline of degree
سالمندی Gerontology
Date of degree
۱۳۹۷/۰۳/۲۹
Body granting the degree
علوم بهزیستی و توانبخشیUniversity of Social Welfare and Rehabilitation))
SUMMARY OR ABSTRACT
Text of Note
هدف :این یک پژوهش اعتبارسنجی نسخه فارسی پرسشنامه مجموعه حداقل دادههای برنامه مراقبت در منزلHC) -Home Care:MDS- (Minimum Data Setاست که به منظور تعیین روایی و پایایی آن در سالمندان ایرانی ساکن خانوار انجام شده است .روش :این یک مطالعه مقطعی از نوع اعتبارسنجی روایی و پایایی ابزارMDS HC ، و نمونههای این مطالعه سالمندان ۶۰ سال و بالاتر ساکن خانوار بازنشسته بودند .براساس روش نمونهگیری تصادفی ۱۶۷ نفر از ایشان انتخاب و به روش مصاحبه، مشاهده و معاینه مورد مطالعه و بررسی قرار گرفتند .یافتهها :مردان ۶۸/۹ و زنان ۳۱/۱ مشارکت کنندگان را با میانگین سنی ۶۸/۴۴ تشکیل دادند .نسخه اولیه از روایی صوری مطلوبی برخوردار بود .پایایی درونی پرسشنامه با محاسبه ضریب آلفای کرونباخ( ۷.۰) مطلوب بود .روایی محتوای سوالات پرسشنامه بر اساس نظر متخصصین مورد قبول بود .در مورد روایی محتوای ابزار مجموعه MDS HC در حیطههای مربوط بودن، واضح بودن و ساده بودن براساس متغیرهای چهار ارزشی، میانگین نمره ۲/۸ از ۷۰ کل نمرات بیشتر و قابل قبول بود ..در رابطه با روایی همزمان زیرمقیاس اختلالات دیداری در ابزار مجموعهHC - MDSبا امتیاز ثبت شده از ابزار چارت بینایی در سالمندان، میزان همبستگی خوبی میان" وضعیت بینایی "در ابزارHC - MDSبا ابزار چارت بینایی e بدست نیامد ..روایی همزمان زیرمقیاس اختلالات خلقی رفتاری در ابزار مجموعهHC - MDSبا امتیاز بدست آمده از ابزار(PHQ۹) ، از ضریب همبستگی اسپیرمن( ۰/۶۴) قابل قبولی برخوردار بوده است .بر اساس نتایج منحنی ROC نقطه برش ۳/۵ =Cut off با حساسیت( ۷۴/۴ درصد) و ویژگی( ۸۳/۸ درصد) و دقت( ۸۱ درصد) برای افتراق بین افراد مبتلا به افسردگی از افراد نرمال بر اساس ابزارPHQ ۹ حاصل گشت .روایی همزمان زیرمقیاس اختلالات خلقی رفتاری در ابزارHC - MDSبا امتیاز بدست آمده از ابزار(GAD-۷ ( lدر سالمندان، بر اساس ضریب همبستگی اسپیرمن( ۰/۶۹۵) بدست آمد .روایی همزمان زیرمقیاس تغذیه در ابزار مجموعهHC - MDSبا امتیاز ثبت شده ازابزار MNA در سالمندان، بر اساس ضریب همبستگی اسپیرمن( ۰/۵۸۱) بدست امد .در ضمن، بر اساس نتایج منحنی ROC نقطه برش ۰/۵ =Cut off با حساسیت( ۸۷/۵ درصد) و ویژگی( ۶۱/۳ درصد) و دقت( ۸۱ درصد) برای افتراق بین افراد مبتلا به سوءتغذیه از افراد تغذیه نرمال براساس پرسشنامه ارزیابی وضعیت تغذیه MNA محاسبه شد .در روایی صوری میزان دقت(Acuracy) ، در ترتیب چیدمان (Order Rank) صورت گرفته توسط سالمندان ۸۰ و در ترتیب چیدمان (Order Rank) صورت گرفته توسط متخصصین نیز ۹۰ محاسبه گردید .از نظر حیطه مطلوب بودن درمورد همه سوالات ابزارHC- MDS، نتایج آزمون tنشان داد که میانگین به طور معناداری از ۲/۱ بیشتر است و در نتیجه روایی ابزارHC - MDSمطلوب است .نتیجه گیری :نسخه فارسی پرسشنامه مجموعه حداقل دادههای برنامه مراقبت در منزلHC)( - MDSبنظر میرسد در سالمندان ایرانی از ویژگیهای اعتبار سنجی( روایی و پایایی) مناسبی در بررسی وضعیت سلامت سالمندان ساکن خانه از نظر نیاز به برنامه مراقبت در منزل در حیطههای گوناگون برخوردار است اما روایی همزمان ابزار در برخی حیطهها مانند شنوایی/ارتباطی، خلقی/رفتاری و وضعیت شناختی و حیطه بینایی نسبت به ابزارهای استاندارد سنجش این حیطهها به پایینترین میزان رسیده بود .به نظر میرسد که این ابزار قابلیت استفاده در مطالعات پژوهشی و اقدامات درمانی را دارد .واژگان کلیدی :مراقبت در منزل، سالمندان، روایی و پایایی، اعتبارسنجی، مجموعه حداقل دادههایMDS -
Text of Note
Purpose: This is a validation study of the Persian version of the Minimum Data Set-Home Care (MDS-HC) questionnaire. This Survey was conducted to determine the validity and reliability of the Iranian elderly Method: This is a cross-sectional study of the validity and reliability of the MDS-HC instrument and the samples of this study was elderly people aged 60 and older living in retired households Results: 68.9 of men and 31.1 of women with an average age of 68.44 participated. Internal reliability of the questionnaire was desirable by calculating the Cronbach's alpha coefficient (0.7). This coefficient was calculated in the cognitive evaluation section = 0.738, in the auditory part = 0.745, in the mood assessment = 0.948, in social function assessment = 0.159, and in the nutritional assessment section = 0.576. Experts accepted the validity of the content of the questions. Regarding the validity of the content of MDS-HC toolkit in terms of relevancy, clarity and simplicity based on four value variables, the average score was 2.8 of 70 of the total score and was acceptable. In terms of relevance for each of the 21 sections, due to the high amount of scores obtained, the validity of the questions is acceptable and, consequently, due to the lack of any difference in all areas, the validity of the areas of auditory / communication, vision, cognitive, mood-behavior and nutrition It has also been accepted. Concerning the simultaneous validity of the subtype of visual disturbances in the MDS-HC collection tool with the registered score of the SNELLEN Scale in the elderly, a good correlation between the 'visual state' in the MDS-HC tool and the SNELLEN Scale tool was not obtained. The simultaneous validity of the cognitive subscale in the tool of the MDS-HC set with the registered score was calculated by using the AMT Scale with respect to the Spearman correlation coefficient (-364/0). The concurrent validity of the subset of behavioral disorder in the MDS-HC collection tool with the score obtained by the Patients Health Questionnaire (PHQ9), has had an acceptable Spearman Correlation Coefficient (0.64). Based on the results of the ROC curve, the cut off point = 3.5 was obtained with sensitivity of (74.4 ) and specifity of (83.8 ) and accuracy of (81 ) for differentiation among people with depression from normal people based on the resulting PHQ9 instrument.. The simultaneous validity of the subscale of nutrition in the MDS-HC collection tool with the registered score of the MNA tool in the elderly, based on the Spearman correlation coefficient (0.581), was obtained. Meanwhile, based on the results of the ROC curve, the cut off point = 0.5 with sensitivity of (87.5 ) and specifity of (61.3 ) and accuracy of (81 ) for differentiation among malnourished males from normal males based on The MNA nutritional status questionnaire was calculated. In formal validity, accuracy in order the rank of elderly was 80 , and in order ranking of experts, 90 was calculated. In terms of the desirable field for all questions of the MDS-HC tool, the results of t-test showed that the mean is significantly higher than 1/2 and therefore the validity of the MDS-HC tool is desirable. Conclusion: The Persian version of the MDS-HC's Minimum Set of Home Care Data (MDS-HC) questionnaire. It seems that in Iranian elderly, validation features (validity and reliability) are appropriate in assessing the health status of the elderly living in the home regarding the need for a care program in home is in different areas, but the simultaneous validity of the MDS-HC tool (in some areas such as hearing / communication, mood / behavior, and cognitive status and vision were lower than the standard tools for measuring these areas). The tool seems to be useful in research studies and therapeutic interventions. Key words: home care, elderly, validity and reliability, validation, MDS-HC minimum data set.
ba
PARALLEL TITLE PROPER
Parallel Title
Psychometric Properties evaluation of Minimum Data Set-Home Care (MDS-HC) in Iranian elderly household residents: A Validity and Reliability Study