بررسی تجربی نوع و میزان آلایندههای آلی فرار منتشره از صنایع چاپ در محیطهای بسته صنایع چاپ( مطالعه موردی :صنایع چاپ مستقر در شهرکهای صنعتی آذربایجان شرقی)
Parallel Title Proper
An experimental study on types and Amounts of emitted pollutants to indoor Air in printing industry (case study: printing industry in industrial towns of east Azerbaijan)
First Statement of Responsibility
/فرشاد احمدیلر
.PUBLICATION, DISTRIBUTION, ETC
Name of Publisher, Distributor, etc.
: مهندسی شیمی و نفت
Date of Publication, Distribution, etc.
، ۱۳۹۹
Name of Manufacturer
، راشدی
PHYSICAL DESCRIPTION
Specific Material Designation and Extent of Item
۶۷ص
NOTES PERTAINING TO PUBLICATION, DISTRIBUTION, ETC.
Text of Note
چاپی - الکترونیکی
DISSERTATION (THESIS) NOTE
Dissertation or thesis details and type of degree
کارشناسی ارشد
Discipline of degree
مهندسی شیمی گرایش طراحی فرآیند
Date of degree
۱۳۹۹/۰۷/۰۲
Body granting the degree
تبریز
SUMMARY OR ABSTRACT
Text of Note
آلودگی هوا و اثرات نامطلوب آن بر روی بهداشت، مسائل اقتصادی و اجتماعی جوامع به حدی است که بسیاری از کشورهای جهان آن را در رأس برنامههای توسعه اقتصادی و اجتماعی خود قرار دادهاند .این یک واقعیت غیرقابل انکار است که محیط زیست هر روز توسط تعداد زیادی سیستم و اجزای آنها و توسط افراد آلوده می شودکه بخش صنعت سهم به سزایی در ایجاد آلودگی هوا دارد .در این میان با توجه به پیشرفت و وابستگی زندگی روزمره بشر به صنایع چاپ، این صنایع نقش مهمی در ایجاد آلودگی ایفا میکنند .این پایان نامه به بررسی تجربی نوع و میزان آلایندههای آلی فرار منتشره از صنایع چاپ در محیطهای بسته صنایع چاپ) مطالعه موردی :صنایع چاپ مستقر در شهرکهای صنعتی آذربایجان شرقی(، پرداخته است .در صنایع چاپ بیشتر آلایندهها از محل ذخیره، استفاده و دفع مواد شیمیایی و زبالههای مایع و جامد ساطع میشوند .جوهرهای چاپی، تونر و کارتریجها حاوی اجزای آلی فرار هستند که پتانسیل ایجاد بو و خطرهای جدی برای سلامتی را دارا هستند .در این پایان نامه غلظت ترکیبات آلی فرار از کارخانه چاپ به روش هلیوگراور اندازهگیری شد و سپس با استفاده از دستگاه کروماتوگرافی گازی جرمی نمونهها آنالیز شد .موقعیت نمونه برداری با توجه به میزان آلوده بودن و مدت زمان حضور کارکنان در آن نقطه انتخاب شده است .نتایج بهدست آمده وجود ترکیبات آلی فرار با غلطتهای مختلف را نشان داد؛ به طوری که غلظت ترکیبات آلی فرار بسته به شدت تهویه و فرآیندهای انتشار متفاوت است نقطه A به دلیل مجاورت با مخازن رنگ بیشترین مقدار غلظت کل ترکیبات آلی فرار را دارد .بعد از آن نقطه C به عنوان نقطه آلوده بدست آمده است .نقطه B به دلیل قرار گرفتن در نزدیکی درب تهویه هوا کمترین مقدار غلظت ترکیبات آلی فرار را دارد و همچنین نقطه D که به عنوان فضای عمومی انتخاب شده بود دارایه مقدار غلظت کل کمتری نسبت به نقاطA و Cاست که این امر بیانگر این نقطه میباشد که با فاصله گرفتن از دستگاه چاپ مقدار غلظت ترکیبات آلی فرار کاهش میباید .همهی مقادیر آلایندههای آلی فرار بهدست آمده چندین برابر مقادیر استانداردهای تعیین شده توسط اداره ایمنی و بهداشت حرفه ای (OSHA) و انستیتوی ملی ایمنی و بهداشت شغلی (NIOSH) است .نکته قابل توجه این است که میزان اثرات گذاری هر آلاینده بر سلامتی انسان با توجه به غلظت ترکیبات آلی فرار و مدت زمان در معرض قرارگیری تغییر میکند .به طوری که در بلند مدت باعث ایجاد سرطان، تحریک چشمها، بینی و گلو مشکلات تنفسی، حالت تهوع و آسیب به دستگاه اعصاب مرکزی بدن انسان شود
Text of Note
Air pollution and its adverse effects on health, economic and social issues of societies are such that many countries in the world put it at the head of their economic and social development programs It is an undisputed fact that the environment is polluted every day with a large number of systems and, their components, and by individuals The industrial sector contributes significantly to air pollution. Meanwhile, due to the progress and dependence of human daily life on the printing industry, these industries play an important role in causing pollution. Thus this dissertation deals to an experimental study on types and amounts of emitted pollutants to indoor air in printing industry (case study: printing industry in industrial towns of east Azerbaijan). Most of the pollutants are emitted from the storage, use and disposal of chemicals and liquid/solid waste. Printing inks, toner and cartridges contain volatile organic components that have the potential to generate odors and can cause serious health risk. In this dissertation, the concentration of volatile organic compounds in four points of the printing plant was measured by heliogravure method. Measurements were performed for 2 hours, every 40 minutes using an air vacuum pump and a sampling balloon, and then the samples were analyzed using gas chromatography. The sampling location is selected according to the degree of contamination and the duration of staff presence at that point. The results showed the presence of volatile organic compounds with different concentrations so that the concentration of volatile organic compounds varies depending on the intensity of ventilation and diffusion processes. Point A has the highest concentration of total volatile organic compounds due to its proximity to the dye tank. Then point C is bad as the infected point. Point B has the lowest concentration of volatile organic compounds due to its proximity to the air conditioning door, and also point D, which is selected as the open space, has a lower total resistance value than points A and B, which indicates It is there that with the distance from the printing press the amount of volatile organic compounds decreased. All levels of volatile organic pollutants obtained are several times the standards set by the Occupational Safety and Health Administration (OSHA) and the National Institute for Occupational Safety and Health (NIOSH). It is noteworthy that the effects of each pollutant on human health vary according to the concentration of volatile organic compounds and the duration of exposure. In the long run, it can cause cancer, irritation of the eyes, nose and throat, respiratory problems, nausea and damage to the central nervous system of the human body
PARALLEL TITLE PROPER
Parallel Title
An experimental study on types and Amounts of emitted pollutants to indoor Air in printing industry (case study: printing industry in industrial towns of east Azerbaijan)