شبیهسازی عددی رفتار میکرومیکسرهای غیرفعال برای کاربرد در تولید سامانههای رهایش دارو
General Material Designation
[پایاننامه]
Parallel Title Proper
Numerical Simulation of Passive Micromixers Behavior for Drug Delivery System Applications
First Statement of Responsibility
/سینا پورحاجی آقا گلستانی
.PUBLICATION, DISTRIBUTION, ETC
Name of Publisher, Distributor, etc.
: مهندسی برق
Date of Publication, Distribution, etc.
، ۱۴۰۰
PHYSICAL DESCRIPTION
Specific Material Designation and Extent of Item
۸۷ص.
Other Physical Details
:
GENERAL NOTES
Text of Note
زبان: فارسی
Text of Note
زبان چکیده: استاد راهنما جلیلی، کیومرث
NOTES PERTAINING TO PUBLICATION, DISTRIBUTION, ETC.
Text of Note
چاپی - الکترونیکی
NOTES PERTAINING TO PHYSICAL DESCRIPTION
Text of Note
مصور، جدول، نمودار
DISSERTATION (THESIS) NOTE
Dissertation or thesis details and type of degree
کارشناسی ارشد
Discipline of degree
مهندسی برق- افزارههای میکرو و نانوالکترونیک
Date of degree
۱۴۰۰/۰۶/۰۱
Body granting the degree
صنعتی سهند
SUMMARY OR ABSTRACT
Text of Note
قابلیت مخلوط کردن سیالات در ابعاد میکرومتری موضوعی مهم در ادوات ریزسیالاتی همانند سامانه آنالیز شیمیایی، آزمایشگاه روی تراشه و سامانه رهایش دارو میباشد .ریزمخلوطکنندههای غیرفعال به دلیل داشتن مزیتهایی از جمله، هزینه ساخت پایین و عدم نیاز به تجهیزات بیرونی برای راهاندازی تراشه به طور گسترده مورد استفاده قرار میگیرند .در ریزمخلوطکنندههای غیرفعال عامل اصلی مخلوطشوندگی نفوذ مولکولی میباشد .با درنظر گرفتن این نکته و با ترکیب دو تکنیک توسعه هندسههای مختلف و ایجاد جریانهای ثانویه میتوان باعث افزایش کیفیت مخلوطشوندگی شد .در این پایاننامه انواع ریزمخلوطکنندههای غیرفعال و روشهای ساخت ادوات ریزسیالاتی مورد بررسی قرار گرفته و درنهایت دو طرح ریزمخلوطکننده غیرفعال برای کاربرد در سامانههای رهایش دارو مورد شبیهسازی قرار گرفت .بعد از بررسی اثرات تغییرات ابعاد کانال و نرخ جریان ورودی بر عملکرد ریزمخلوطکنندهها، ابعاد و عملکرد بهینهسازی شده و امکان سنجی ساخت تراشه مورد مطالعه قرار گرفت .برای اجرای شبیهسازی نرمافزار المان محدود کامسول، نسخه ۶.۵ مورد استفاده قرار گرفت
Text of Note
10-10 m2/s, mixing efficiency of more than 90 is achieved after 30 mm and 26 mm (approximately one-third of the total channel length) respectivelyMicrofluidic devices receiving increasing attention due to considerable advantages, including: Capable of containing extremely low volume of fluid, small dimensions, low fabrication costs, not high analysis time, high sensitivity. One of the most basic components which has significant impact on the performance and sensitivity of LOCs is micromixer. passive micromixers are much easier to integrate, but based on their structure, they often require complicated fabrication processes. Mixing in 2D spiral-channel micromixers basically depends on the advection caused by the secondary flow or Dean vortices created by the inertia force. To achieve high mixing efficiency (ME) several loops are required. Hence, to increase the mixing effects of spiral mixers creative structures using few numbers of loops have been proposed. In this thesis, various types of passive micromixers and micro-fabrication methods are studied. Inaddition, two recommended spiral-channel micromixers were designed and simulated for drug delivery applications. A series of simulations were caried out to evaluate the effects of channel width, channel depth, gap between loops and flowrate on the micromixers mixing efficiency. Finally, after optimizing the designs dimensions and performance, the chip was fabricated. COMSOL, version 5.6 is used to run simulations. Recommended spiral designs have the potential to create and strengthen the secondary flow. Moreover, L-turns during the channel lead to the displacement of velocity profile over the channel width. These features have increased the contact are of the two fluids and ultimately leads to an increment in the quality of the mixture. In both designs, for the flow rates of 25 l/min and molecular diffusion coefficient of 1