بررسی تاثیر MLSS بر روی عملکرد و گرفتگی غشای PVC طی تصفیه پساب داروسازی
General Material Designation
[پایاننامه]
Parallel Title Proper
Synthesis of PU/PDMS copolymers and investigation of their physical and mechanical properties
First Statement of Responsibility
/فاطمه سعیدیان
.PUBLICATION, DISTRIBUTION, ETC
Name of Publisher, Distributor, etc.
: مهندسی شیمی
Date of Publication, Distribution, etc.
، ۱۴۰۰
PHYSICAL DESCRIPTION
Specific Material Designation and Extent of Item
۷۰ص.
Other Physical Details
:
GENERAL NOTES
Text of Note
زبان: فارسی
Text of Note
زبان چکیده: فارسی
NOTES PERTAINING TO PUBLICATION, DISTRIBUTION, ETC.
Text of Note
چاپی - الکترونیکی
NOTES PERTAINING TO PHYSICAL DESCRIPTION
Text of Note
مصور، جدول، نمودار
DISSERTATION (THESIS) NOTE
Dissertation or thesis details and type of degree
کارشناسی ارشد
Discipline of degree
مهندسی شیمی- بیوتکنولوژی
Date of degree
۱۴۰۰/۰۷/۰۱
Body granting the degree
صنعتی سهند
SUMMARY OR ABSTRACT
Text of Note
کنترل کیفیت فاضلاب و تصفیه مؤثر، جهت حذف آلودگیها و استفاده مجدد از آب بازیافت شده، عامل ارزشمندی جهت جلوگیری از نفوذ آلودگیها به محیط زیست و صرفهجویی در استفاده از منابع آبی میباشند .به منظور تصفیه فاضلابهای صنعتی و شهری و عملی ساختن اصل بازچرخانی آب، در بسیاری از کشورهای پیشرفته دنیا از فناوری جدیدی با نام بیوراکتور غشایی به جای لجن فعال متعارف استفاده میشود .بیوراکتورهای غشایی تلفیقی از یک سیستم بیوراکتور و یک ماژول غشایی میباشد که به کارگیری این فرآیند موجب حذف فرآیند تهنشینی و گندزدایی مورد استفاده در شیوههای مرسوم لجن فعال میگردد .کیفیت آب بدست آمده نسبت به آب حاصل از سامانههای معمولی تصفیه فاضلاب بیشتر میباشد و عملیات ضدعفونی کمتری نیز انجام میشود و همچنین زمان ماند مورد نیاز برای تهنشینی در سامانههای معمولی به میزان قابل توجهی با استفاده از فرایند غشایی کاهش مییابد .در این کار تحقیقاتی اثر پارامتر MLSS در سه غلظت ۱۰۰۰، ۲۰۰۰ و ۳۰۰۰ میلیگرم بر لیتر بر روی گرفتگی غشا بررسی شد .نتایج حاصل نشان داد با افزایش غلظت لجن، شار خروجی از غشا به شدت کاهش مییابد .بنابراین، بالاترین شار با مقدار ۱۰۹ لیتر بر متر مربع بر ساعت و کمترین گرفتگی کلی غشا با ۴۸/۴۸ درصد در MLSS ۱۰۰۰ میلیگرم بر لیتر حاصل شد .در مقابل، با این که بیوراکتور غشایی در تمامی غلظتها قادر به حذف COD تا بالای ۷۰ درصد بود، اما بیشترین میزان حذف در غلظت ۳۰۰۰ میلیگرم بر لیتر به مقدار ۸۶/۵۷ درصد به دست آمد .در ادامه با تستهای مدلسازی گرفتگی و همچنین آنالیزFTIR ، نتیجه حاصل شد که عملکرد میکروارگانیسمها در بیوراکتور غشایی به شدت تحت تاثیر MLSS قرار میگیرد و این مواد میکروبی تحت تاثیر غلظت لجن، نقش کلیدی در گرفتگی غشا و همچنین حذف آلایندهها از فاضلاب را دارند.
Text of Note
Effective wastewater quality control and treatment to remove pollution and reuse recycled water are valuable factors in preventing pollution from entering the environment and saving water resources. In order to treat industrial and municipal wastewater and implement the principle of water recycling, in many developed countries of the world, a new technology called membrane bioreactor is used instead of conventional activated sludge. Membrane bioreactors are a combination of a bioreactor system and a membrane module that use this process to eliminate the precipitation and disinfection process used in conventional activated sludge methods. The quality of water obtained is higher than that of conventional wastewater treatment systems, and less disinfection is performed, and the retention time required for settling in conventional systems is significantly reduced by the use of a membrane process. In this regard, different types of operational parameters affect the quality and amount of purified water from the membrane bioreactor process. Therefore, in this study, after stating the necessity and importance of removing pollutants from wastewater and various methods used to remove these materials, studies on MBR processes to treat wastewater containing pollutants and after explaining the mechanism of these processes, Factors and parameters affecting the performance of membrane bioreactors are investigated. In this research work, the effect of MLSS parameter in three concentrations of 1000, 2000 and 3000 mg / l on membrane fouling was investigated. The results showed that with increasing sludge concentration, the output flux from the membrane decreases sharply. Therefore, the highest flux of 109 liters per square meter per hour and the lowest total membrane fouling with 48.48 was obtained in MLSS 1000 mg / l. In contrast, although membrane bioreactors were able to remove COD up to 70 at all concentrations, the highest removal rate was 86.57 at 3000 mg / L. Then, with fouling modeling tests and FTIR analysis, it was concluded that the performance of microorganisms in membrane bioreactors is strongly affected by MLSS and these microbial substances play a key role in fouling the membrane as well as removing contaminants from wastewater.
ba
PARALLEL TITLE PROPER
Parallel Title
Synthesis of PU/PDMS copolymers and investigation of their physical and mechanical properties