• Home
  • Advanced Search
  • Directory of Libraries
  • About lib.ir
  • Contact Us
  • History

عنوان
Review of fan-use rates in field studies and their effects on thermal comfort, energy conservation, and human productivity

پدید آورنده
He, Yingdong; Chen, Wenhua; Wang, Zhe; Zhang, Hui

موضوع

رده

کتابخانه
Center and Library of Islamic Studies in European Languages

محل استقرار
استان: Qom ـ شهر: Qom

Center and Library of Islamic Studies in European Languages

تماس با کتابخانه : 32910706-025

NATIONAL BIBLIOGRAPHY NUMBER

Number
LA7hx9338z

TITLE AND STATEMENT OF RESPONSIBILITY

Title Proper
Review of fan-use rates in field studies and their effects on thermal comfort, energy conservation, and human productivity
General Material Designation
[Article]
First Statement of Responsibility
He, Yingdong; Chen, Wenhua; Wang, Zhe; Zhang, Hui

SUMMARY OR ABSTRACT

Text of Note
This paper is a literature review of field studies on fan-use rates and their effects on thermal comfort, energy conservation, and human productivity. In the assessed literature, fans are more popular in Asia, and more used in mixed-mode (MM) and naturally ventilated (NV) buildings than in air-conditioned (AC) buildings. On the basis of collected fan-use models, probit regression models of fan-use rates and ambient environments were obtained and indicate that the essential trigger of fan-use is a warm environment rather than building types. This result helps us to understand the control behaviors and comfort requirements of occupants. Also, fans could provide benefits in three aspects: widening neutral temperatures, saving energy, and improving occupants' productivity. First, using fans in buildings elevates the neutral temperature and the upper limit of neutral zone (0.5 thermal sensation scale) averages by about 3 K in ranges from 25.7℃ to 28.7℃ and 27.5℃ to 30.7℃, respectively. Second, fan-use reduces AC-use rates in MM buildings in summer. The regression models based on the collected AC-use rate models illustrate that, on average, AC-use is expected to be reduced by about 15% in summer when fans are used. Third, providing occupants access to fans could improve occupants' productivity. Based on the limited data available, a 3-K temperature extension is achieved by fans ensuring productivity not decreasing. This review could shed some light on the extension of the neutral temperature range, predictions of MM buildings' energy consumptions, and methods to enhance productivity. Additionally, this review suggests some valuable directions for future research on fans.

SET

Date of Publication
2019
Title
UC Berkeley

ELECTRONIC LOCATION AND ACCESS

Electronic name
 مطالعه متن کتاب 

[Article]
275578