"This document uses both the international system of units (SI) and customary units."
"Updates and replaces the previous standard, ASCE/SEI 24-05."--Page 4 of cover
Includes bibliographical references and index
General -- Basic requirements for flood hazard areas that are not identified as coastal high hazard areas and coastal A zones -- High risk flood hazard areas -- Coastal high hazard areas and coastal A zones -- Materials -- Dry floodproofing and wet floodproofing -- Attendant utilities and equipment -- Building access -- Miscellaneous construction -- Commentary: C1. General -- C2. Basic requirements for flood hazard areas that are not identified as coastal high hazard areas and coastal A zones -- C3. High risk flood hazard areas -- C4. Coastal high hazard areas and coastal A zones -- C5. Materials -- C6. Dry floodproofing and wet floodproofing -- C7. Attendant utilities and equipment -- C8. Building access -- C9. Miscellaneous construction -- C10. References
0
ASCE/SEI 24-14
Building, Stormproof-- Standards-- United States
Flood damage prevention-- Standards-- United States